Why Zinc and Galvalume Have Different Coating Mass to Micron Conversions

Nov 24, 2026

Leave a message

Technical buyers and traders frequently convert coating mass figures into microns using a single factor when preparing purchase orders. The practice works for pure zinc but produces misleading thickness numbers for aluminum-zinc (Galvalume) coatings, creating acceptance disputes when measured thickness does not match the expected micron value.

Density Difference Between Pure Zinc and Aluminum-Zinc Alloys

Pure zinc used in conventional hot-dip galvanizing has a density of approximately 7.14 g/cm³. Industry references, including conversion tables derived from ASTM A653 and GalvInfoNote data, commonly apply 7.1–7.2 g/cm³ to account for minor iron-zinc alloy layers formed during continuous galvanizing. In contrast, the 55% aluminum–43.5% zinc–1.6% silicon alloy typical of Galvalume (AZ coatings under EN 10346 and ASTM A792) has a density of about 3.7–3.8 g/cm³.

info-738-414 info-623-491

Because thickness in micrometres is calculated as mass per side (g/m²) divided by density (g/cm³), the same mass produces a thicker coating when density is lower. This relationship is standard in continuous hot-dip lines operated in Europe, China, and North America, where coating mass is verified by triple-spot strip-weigh-strip methods and thickness is reported only as an approximate derived value.

Common Conversion References

A Z275 zinc coating specifies a minimum total coating mass of 275 g/m² on both sides (EN 10346 / ASTM A653 G90 equivalent). This equates to roughly 137.5 g/m² per side and a calculated single-side thickness of about 19–20 µm using a density of 7.14 g/cm³.
 

An AZ150 Galvalume coating specifies a minimum total mass of 150 g/m² on both sides. With a density near 3.8 g/cm³, the same calculation yields approximately 20 µm per side-similar thickness to Z275 despite substantially lower mass. Z120 zinc, by comparison, yields roughly 8–9 µm per side.
 

These figures appear consistently in EN 10346 guidance tables and GalvInfoNote coating-factor summaries. Actual measured thickness on a given coil can vary ±10–15% because of surface roughness and local bath chemistry, which is why standards treat micron values as informational rather than acceptance criteria.

 

Coating type Typical total mass (both sides) Approx. single-side thickness Density characteristic Conversion note
Pure zinc Z275 275 g/m² ~19–20 µm Higher (~7.14 g/cm³) Do not apply same factor to AZ coatings
Aluminum-zinc AZ150 150 g/m² ~20 µm Lower (~3.8 g/cm³) Same mass produces greater thickness
Pure zinc Z120 120 g/m² ~8–9 µm Higher (~7.14 g/cm³) Requires separate calculation

Why the Same Micron Target Cannot Be Used for Both Coatings

Applying a zinc-derived micron number to an aluminum-zinc order understates the actual coating thickness that will be delivered for a given mass, or forces the supplier to apply excess mass to meet an arbitrary micron limit. Conversely, demanding a zinc-style micron value on Galvalume can result in rejection of material that fully meets the mass specification in EN 10346 or ASTM A792. Because corrosion performance and formability are primarily controlled by coating mass and alloy composition rather than by a single micron figure, mismatched conversion creates unnecessary commercial friction during mill-certificate review and third-party inspection.
info-547-365 info-738-393

Prefer Coating Mass (g/m²) in Specifications

Purchase orders and technical inquiries should state the coating designation and mass requirement (for example, Z275 or AZ150) and reference the governing standard. Micron values may be noted as approximate for information only. This approach aligns with the verification methods used on continuous lines and reduces the risk of dispute when material arrives at fabrication plants or agricultural project sites.
 

When preparing specifications for roofing, greenhouse structures, or silos, review the product data sheets and technical conversion tables that list both mass and typical thickness ranges side by side. Clear mass-based language keeps communication consistent between buyer, mill, and inspector.
 

For further details on coating selection or product availability, visit our galvanized steel coil and Galvalume steel coil pages, or contact us for technical support.